Adam Equipment ABK Series Specifiche

Navigare online o scaricare Specifiche per Bilance da cucina Adam Equipment ABK Series. Adam Equipment ABK Series Specifications Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 1 - ABK, AFK Scales

© Adam Equipment Company 2011 Adam Equipment ABK, AFK Scales (P.N. 3116611364 - Revision A, December 2011)

Pagina 2

9 | P a g e © Adam Equipment Company 2011 4.0 KEY DESCRIPTIONS [>Z/T<] If near zero, Sets the zero point fo

Pagina 3 - CONTENTS

10 | P a g e © Adam Equipment Company 2011 [Func/C] Selects the Functions of the scale. If the scale is weighing, it w

Pagina 4

11 | P a g e © Adam Equipment Company 2011 5.0 DISPLAYS The LCD display will show a value and a unit to the right of the digits.

Pagina 5 - 1.0 INTRODUCTION

12 | P a g e © Adam Equipment Company 2011 6.0 OPERATION 6.1 ZEROING THE DISPLAY • You can press the [Z/T] key at any time to s

Pagina 6 - 2.0 SPECIFICATIONS

13 | P a g e © Adam Equipment Company 2011 • Press the [Z/T] key to tare the scale. The weight that was displayed is st

Pagina 7

14 | P a g e © Adam Equipment Company 2011 6.4 PARTS COUNTING If parts counting is enabled, See section 7.4, it is possible to co

Pagina 8 - 3.0 INSTALLATION

15 | P a g e © Adam Equipment Company 2011 • Press the [Pcs/] key to return to normal weighing. Press the [Pcs/] key

Pagina 9

16 | P a g e © Adam Equipment Company 2011 BOTH LIMITS SET The display will show OK when the weight is between the limits

Pagina 10 - DESCRIPTIONS

17 | P a g e © Adam Equipment Company 2011 NOTE: Weight must be more than 20 scale divisions for check weighing to operate. Below

Pagina 11

18 | P a g e © Adam Equipment Company 2011 6.6 ACCUMULATED TOTAL • The scale can be set to accumulate manually by press

Pagina 12 - 5.0 DISPLAYS

© Adam Equipment Company 2011 Easy Reference: Model name of the scale: Serial number of the unit: Software re

Pagina 13 - 6.0 OPERATION

19 | P a g e © Adam Equipment Company 2011 6.7 PERCENT WEIGHING The scale can be set to perform percent weighing. See Section 7

Pagina 14

20 | P a g e © Adam Equipment Company 2011 comparison to the capacity of the system. A smaller weight will show only “100%” while a

Pagina 15

21 | P a g e © Adam Equipment Company 2011 6.8 ANIMAL (DYNAMIC) WEIGHING The scale can be set to animal (dynamic) weighing for w

Pagina 16

22 | P a g e © Adam Equipment Company 2011 6.8.1ANIMAL WEIGHING PROCEDURE • With the platform empty the display will show

Pagina 17

23 | P a g e © Adam Equipment Company 2011 7.0 USER PARAMETERS Pressing the [Func/C] key during normal operation allows the user t

Pagina 18

24 | P a g e © Adam Equipment Company 2011 Parameter Description Options Default setting F1 Lo Set Low limit. Use the [Unit

Pagina 19

25 | P a g e © Adam Equipment Company 2011 [Print/M+/Esc] again, the scale will exit the User Parameter section and return

Pagina 20

26 | P a g e © Adam Equipment Company 2011 the Accumulation AC oFF C5 Ln Select Language EnGLi (English) FrEnCH (French) GErmAn

Pagina 21

27 | P a g e © Adam Equipment Company 2011 This group of parameters is used to control the operation of the scale. Parameter Des

Pagina 22

28 | P a g e © Adam Equipment Company 2011 8.0 BATTERY OPERATION • The scales can be operated from the battery if desir

Pagina 23

1 | P a g e © Adam Equipment Company 2011 CONTENTS 1.0 INTRODUCTION ...

Pagina 24 - PARAMETERS

29 | P a g e © Adam Equipment Company 2011 3124 9.0 RS-232 INTERFACE The ABK/AFK indicator is supplied with bi-direction

Pagina 25

30 | P a g e © Adam Equipment Company 2011 Data Format-Normal Output: Only weight value along with the weighing unit is printed. I

Pagina 26 - Baud Rate

31 | P a g e © Adam Equipment Company 2011 Data Format- Memory Recall Output: Data Format- Continuous Output- Normal weighing:

Pagina 27 - PRINT SETTINGS

32 | P a g e © Adam Equipment Company 2011 Description ENGLISH FRENCH GERMAN SPANISH Net weight Net Wt. Pds Net Net-Gew Ps

Pagina 28

33 | P a g e © Adam Equipment Company 2011 10.0 RELAY INTERFACE The indicator is supplied with drivers to control external relay

Pagina 29 - OPERATION

34 | P a g e © Adam Equipment Company 2011 Connections to the drivers: Connections are made to the PCB, Connector P1. The conne

Pagina 30 - INTERFACE

35 | P a g e © Adam Equipment Company 2011 11.0 CALIBRATION The scale can be calibrated using the following procedure. To en

Pagina 31

36 | P a g e © Adam Equipment Company 2011 12.0 SERVICE SECTION The scales will allow entry to the parameters if the

Pagina 32

37 | P a g e © Adam Equipment Company 2011 The parameters available are: “F4 Int” Initial Zero Range “F5 rEZ” Re-Zer

Pagina 33

38 | P a g e © Adam Equipment Company 2011 12.3 PARAMETER DETAILS 12.3.1 F1 -CALIBRATION To enter the calibration parameter, p

Pagina 34 - 10.0 RELAY

2 | P a g e © Adam Equipment Company 2011

Pagina 35

39 | P a g e © Adam Equipment Company 2011 12.3.3 F3 – CAPACITY/ WEIGHING UNIT/INCREMENT To enter this parameter, press the [Z/T]

Pagina 36 - 11.0 CALIBRATION

40 | P a g e © Adam Equipment Company 2011 12.3.4 F4 –INITIAL ZERO RANGE To enter this parameter, press the [Z/T] key when “F4 int

Pagina 37 - SECTION

41 | P a g e © Adam Equipment Company 2011 12.3.9 F9 –LOW VOLTAGE DETECTION This parameter allows detection of low voltage when t

Pagina 38

42 | P a g e © Adam Equipment Company 2011 13.0 ERROR CODES ERROR CODES DESCRIPTION SUGGESTIONS - -oL - - Over-range Remove w

Pagina 39

43 | P a g e © Adam Equipment Company 2011 14.0 REPLACEMENT PARTS AND ACCESSORIES If you need to order any spare parts an

Pagina 40

44 | P a g e © Adam Equipment Company 2011 16.0 WARRANTY STATEMENT Adam Equipment offers Limited Warranty (Parts and Labou

Pagina 41

45 | P a g e © Adam Equipment Company 2011

Pagina 42

© Adam Equipment Company 2011 Manufacturer’s Declaration of Conformity This product has been manufactured in accord

Pagina 43 - 13.0 ERROR

© Adam Equipment Company 2011 ADAM EQUIPMENT is an ISO 9001:2008 certified global company with more than 35 years experie

Pagina 44

3 | P a g e © Adam Equipment Company 2011 1.0 INTRODUCTION • The ABK/AFK scales provides an accurate, fast and versati

Pagina 45 - STATEMENT

4 | P a g e © Adam Equipment Company 2011 2.0 SPECIFICATIONS Model # ABK 8 ABK 16a ABK 16 ABK 35a ABK 32 ABK 70a ABK 60 ABK 130a

Pagina 46

5 | P a g e © Adam Equipment Company 2011 Model # AFK 75/165a AFK 150/330a AFK 300/660a AFK 600/1320a Maximum Capacity 75kg/16

Pagina 47

6 | P a g e © Adam Equipment Company 2011 3.0 INSTALLATION 3.1 UNPACKING The ABK/AFK scales have already been adjusted to work wi

Pagina 48

8 | P a g e © Adam Equipment Company 2011 3.3 SETTING UP THE SCALES • The pillar is attached to the base using a bracket